5. Drain the filter medium (see "Exchanging the filter medium").
If you are using filter balls, wash them by hand and let them dry completely. If you are using sand,
pour the sand into a suitable container (e.g. bucket) and store this in a dry place.
6. Rinse the filter system with tap water.
7. Let the filter system dry completely.
8. Press and hold down the valve lever
on the valve head
.
9. Turn the valve lever to the "WINTER" position and let go.
The device can be stored over the winter.
Troubleshooting
Problem Possible cause Remedy
The pressure on the manometer
exceeds 1 bar.
The filter medium is dirty. Carry out backflushing.
The inlet nozzle is closed. Open the inlet nozzle.
The water flow in the vessel is
blocked because
"GESCHLOSSEN" mode is
active.
Select a different mode.
The filter balls are dirty. Remove and wash the filter balls by hand.
Exchange the filter balls if necessary.
Air bubbles escape from the
injection nozzle.
The pump is sucking in air. Check all lines and seals for leaks.
Retighten the threaded rings.
The pump is not getting enough
water or the system pressure is too
low.
The water level in the pool is too
low.
Raise the water level in the pool.
The prefilter basket (if present)
is clogged.
Empty the prefilter basket.
The suction line is clogged. Clean the suction line.
The pump is not running. The timer is set. Check the running time on the timer.
The external timer is set. Check the running times on the external
timer.
After the pump has been switched
on, the timer LED does not flash
and the pump does not start up.
The pump has no power. Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
The pump is defective. Contact customer service.
There is filter medium in the pool Quartz filter sand was topped
up.
Backflush the system until the water runs
clear. See section "Backflushing".
Defective screens in the filter
vessel.
Check the screens for damage and
replace if necessary.
If the problem cannot be solved, contact the customer service listed on the last page.