0478-131-3050-A
29
English 
10 Installing the Robotic Mower
► Cut the ends of the perimeter wire (5 and 6) so that 
approximately 15.7 in. (40 cm) is available for insertion 
into the docking station. Additional length is not needed.
► Do not coil excess wire behind the docking station.   
Excess wire can interfere with the operation of the robotic 
mower.
To connect the perimeter wire to the panel:
► Use a suitable tool to strip a = 0.236 in. (6 mm) from the 
of the left perimeter wire (5) end and twist the perimeter 
wire strands.
► Twist both perimeter wire ends together (5 and 6).
► Open the panel, @ 10.3.
► Press and open the left clamping lever (8).
► Insert the stripped perimeter wire end (5) into the clamping 
block as far as it will go.
► Close the clamping lever (8)
► Use a suitable tool to strip a = 0.236 in. (6 mm) from the 
end of the right perimeter wire (6) and twist the perimeter 
wire strands.
► Press and open the right clamping lever (9).
► Insert the stripped perimeter wire end (6) into the clamping 
block as far as it will go.
► Close the clamping lever (9)
► Close the panel. Take care not to pinch the power supply 
cord or the perimeter wire.
5
6
0000-GXX-5351-A0
5 + 6
a
5
0000-GXX-5352-A0
5
8
6
a
0000-GXX-5353-A1