2.Basic splicing operationOptical fiber splicing
2. Basic splicing operation
Symptom
Possible cause Troubleshooting Refer to
Kink or offset
There is dust on the V-groove
and bare fiber pads.
Clean the V-groove and bare
fiber pads. See the illustra-
tions below.
P.3-1 Cleaning V-grooves,
P.3-2 Cleaning bare fiber
pads
Arc power is not optimum.
Perform an arc test to make
sure the splicer gives “Arc
OK”.
P.2-15 Arc test
The melt back distance is not
equal between the left and
right fibers.
Bulging
Overlap is too big. Decrease the Overlap.
P.4-6 Splice program ed-
itable items
Arc power is not optimum.
Perform an arc test to make
sure the splicer gives “Arc OK”.
P.2-15 Arc test
There is dust on the V-groove
and bare fiber pads.
Clean the V-groove and bare
fiber pads. See the illustra-
tions below.
P.3-1 Cleaning V-grooves,
P.3-2 Cleaning bare fiber
pads
Neck-down
Overlap is too small. Increase the Overlap.
P.4-6 Splice program ed-
itable items
Arc power is not optimum.
Perform an arc test to make
sure the splicer gives “Arc
OK”.
P.2-15 Arc test
There is dust on the V-groove
and bare fiber pads.
Clean the V-groove and bare
fiber pads. See the illustra-
tions below.
P.3-1 Cleaning V-grooves,
P.3-2 Cleaning bare fiber
pads
Bubble
Prefusion time is too short. Increase the Prefusion time.
P.4-6 Splice program ed-
itable items
There is dust on the fiber.
Cleave the fiber again.
Instruction manual that
came with the cleaver you
use.
The cleave angle of the fiber
exceeds the allowable limit.
White line
Arc power is not optimum.
Perform an arc test to make
sure the splicer gives “Arc
OK”.
P.2-15 Arc test
Prefusion time is too short. Increase the Prefusion time.
P.4-6 Splice program ed-
itable items
Black line
There is dust on the fiber. Cleave the fiber again.
Instruction manual that
came with the cleaver you
use.
Splice error possible cause and troubleshootin
g
Cleaning V-groove and bare fiber pads
Do a visual check of the splice point viewed on the monitor. If any symptoms
below appear or an estimated loss is too high, read the troubleshooting
against the symptom and re-do the entire splicing procedures from the
beginning.
A white line, black line or vertical line appears at the splice point when MMF,
dissimilar fibers or fibers with different diameters are spliced. But it does
not affect splice quality, such as splice loss, tensile strength, and etc.
Bare fiber pads
V-groove