2-14
2.Basic splicing operationOptical fiber splicing
2. Basic splicing operation
1: Open the hood and the fiber
coating clamp lid.
2: Place the fiber in the splicer so the
fiber end is between the edge of
the v-groove and the electrodes.
Electrode
V-groove
Fiber
3: Close the fiber coating clamp lid.
Do not touch the fiber end
face against any surface.
4: Repeat step 2 to 4 for the other
fiber.
5: Close the hood.
6: Start an arc test or the splicin
g
process.
Inserting fibers into the splicer