EasyManua.ls Logo

Sumitomo 82C+ - Splice Protection

Sumitomo 82C+
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-28
2. Basic splicing operationDrop cable splicing
2. Basic splicing operation
Splice protection
1: Make the left hand oven clamp linked
with the oven lid and the right hand
oven clamp independent.
Open the oven lid and oven clamps.
Open the hood and all lids of the fiber
holders.
4: While applying a slight tension to the
cable end, close the left hand oven
clamp and oven lid. Start the heat
shrink process.
5: After the heat shrink process is
complete, open the oven lid and
oven clamps and take out the cable.
3: While maintaining a slight tension on
the cable ends, transfer the cable to
the heat shrink oven and close the
right hand oven clamp.
2: Take out the cable and slide the fiber
protection sleeve onto the fiber. Make
sure that the protection sleeve is
centered over the splice and at least
5mm of the sleeve overlaps the cable
sheath at each end of the splice.
<1>Pull the cable
<2>Close the lid
While maintaining a slight
tension on the cable ends,
close the oven clamps.
Drop cable
Fiber protection sleeve
At least 5mm of the sleeve must overlap the
cable sheath at each end of the splice.
Pay attention not to bend and
flex the cable. Failure to do so
can cause the splice to break.
Drop cable

Table of Contents