4-11
4.Splice programAttenuation splice mode
4. Splice program
5: Select “ATTN Coef.” to edit
the value.
6: Enter the value of ATTN Coef.
If the value is increased, fiber
offset will become large and a
splice loss will be higher. If the
value is decreased, a splice loss
will be lower.
7: Tap Set icon ( ) icon to
perform a splice.
Check an actual splice loss. If the
actual splice loss still does not
match the target splice loss, go
back to step 5~6 to adjust ATTN
Coef again.
* Touch the ATTN icon on the arc
pause screen to go to the setting
screen.
Item Details
Operator Administra-
tor
View Edit View Edit
Target Loss Sets the target splice loss for attenuation.
-
Fiber Core Off-
set for ATTN
Sets the target core offset value for attenuation.
This parameter will be changed in association with
“Target loss”.
-
ATTN Coef.
This parameter is the attenuation splice
coefficient. If actual splice loss measured does not
match “Target Loss”, this parameter can be used
to adjust.
-