INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
14 SUMMIT PUMP MODEL CCFM GENERAL PURPOSE
7.3.1 Grease
Acceptable greases are petroleum base or synthetic meeting NLGL grade 2. Temperature range
of the grease is -60°F to 350°F, this grease is not recommended for temperatures above 350°F.
Table 7-1: Acceptable Greases
Acceptable Greases
Citgo Mystic EP2
Keystone 81EP2
Mobil Mobil Grease XHP222
Mobil Synthetic SCH 100
7.3.2 Lubrication Frequency
Lubrication frequency depends on environment and service factors. Each operator of the pump is
responsible for determining these factors as it is impractical to identify all operating situations.
Table 7-2 below is a general recommendation of lubrication frequency.
7.3.3 Lubrication Amount
Bearings for frame 1 and 2 will require approximately 1.5oz. for inboard bearings (16) and
approximately 1.75oz. of grease for outboard bearings (18). Follow these amounts when
lubrication frequency is required.
Little operation. About 10 hours per week.
Air is free of dust and chemicals
8 hour operation per 5 day week.
Air is free of dust and harmful chemicals
Intense operation. 24 hour service with limited dust and/or
chemicals. Outdoor operation
Table 7-2: Lubrication Frequency