INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
16 SUMMIT PUMP MODEL CCFM GENERAL PURPOSE
9 TROUBLESHOOTING
9.1 PUMP PROBLEMS
Pump turns, no flow. 1,2,3,4,5,8,9,10,11,12,13,14,15,16,21,22
Pump flow rate below expected capacity. 1,2,3,4,5,8,9,11,12,13,15,16,17,18,21
Pump will not produce rated pressure. 1,2,3,4,5,10,11,13,15,16,18,21,22,26,27
Pump develops too much pressure. 6,8,9,12,27
Pump no longer self-primes. 1,2,3,4,5,7,8,10,11,12,13,14,15,16,18,19,21,22
Pump won't turn/motor overloads. 2,4,5,6,7,8,9,15,18,19,20,21,23,24,25,26
Pump is very noisy/excessive vibration. 1,2,3,4,5,6,7,10,11,12,13,14,15,16,17,18,19,20,22,24,25,26
Pump runs hot. 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26
Pump seals short life. 1,2,3,4,5,6,7,8,9,11,12,13,14,15,1617,18,19,20,23,24,25
Excessive internal wear. 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,19,20,21,22,23,24,25
9.2 PROBABLE CAUSE AND REMEDY.
Air leaking into the pump. 3
Liquid temperature higher than stated.
Viscosity higher than stated. 5
Pump running too fast for application.
Losses in system are greater than calculated
Suction or differential pressure too high. 9
Suction valve partially open.
Discharge valve not open or partially open.
Clogged strainer. 13
Minimum submergence not met
Velocity in suction pipe too high
Casing ring and Impeller hub worn. 18
Improper seal installed. 19
Velocity in suction is too low for solids
Suction lift if too great and/or pump is not primed
Drive not sized for horsepower required.
Pressure gauges are not near pump suction and discharge