EasyManuals Logo

Sun Microsystems Fire V240 User Manual

Sun Microsystems Fire V240
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
2-14 Sun Fire V210 and V240 Servers Administration Guide December 2005
FIGURE 2-5 Removing a DVD-ROM Drive (Sun Fire V240 Server)
2.7 Removing and Replacing a Power
Supply Unit
The Sun Fire V240 server has dual-redundant power supplies. You can swap one
power supply while the other is still running.
The Sun Fire V210 server has a single power supply. Swapping it requires the
attention of qualified service personnel. Refer to the Sun Fire V210 and V240 Servers
Service Manual (819-4207-10).
2.7.1 Removing a Power Supply Unit
1. At the ALOM prompt, type:
sc> removefru -y PSx

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Fire V240 and is the answer not in the manual?

Sun Microsystems Fire V240 Specifications

General IconGeneral
BrandSun Microsystems
ModelFire V240
CategoryServer
LanguageEnglish

Related product manuals