Quick Operation Reference
Away Arm [ User Code ] [ 9 ] or [ User Code ] [ AWAY ]
Away Arm(multi-partitions) [ User Code ] [ 9 or Away] + [select partition][ * ]
Home Arm [ User Code ] [ 8 ] or [ User Code ] [ HOME ]
Home Arm(multi-partitions) [ User Code ] [ 8 or Home] + [select partition][ * ]
Quick Away Arm [ # ] [ AWAY ] or [ # ] [ 9 ] or hold [ AWAY ] 3s
Quick Home Arm [ # ] [ HOME ] or [ # ] [ 8] or hold [ HOME ] 3s
Disarm [ User Code ] [ 0 ]
Disarm(multi-partitions) [ User Code ] [ 0] + [select partition][ * ]
Bypass [ User Code ] [ 6 ] [ Zone Number ] [ * ]
Bypass [ User Code ] [Bypass] [ Zone Number ] [ * ]
Review [ User Code ] [ 4 ]or [ User Code ] [Review]
Panic alarm hold [ PANIC ] 3s or [ # ] [ 1 ]
Medical alarm hold [ Medical ] 3s or [ # ] [ 2 ]
Fire alarm hold [ Fire ] 3s or [ # ] [FIRE]
Walk-test [ User Code ] [ 5 ]
Duress alarm [ User Code with Last Digit + 1 ]
Programming mode [ Master Code ] [ 7 ] [ Address ] [ Value ] [ * ]
Change Master Code [ Master Code ] [ 7 ] [ 0401 ] [ New Code ] [ ]
Enter User Code [ Master Code ] [ 7 ] [ 0403-0420 ] [ New Code ] [ ]
Program Master partition [ Master Code ] [ 7 ] [ 0451 ] [ partition] [ ]
Program User partition [ Master Code ] [ 7 ] [ 0453-0470 ] [ partition ] [ ]
Activate Personal Dialer [ Master Code ] [ 7 ] [ 1601 ] [ 1 ] [ * ]
Address 1601 for partition 1 , Address 2601,3601,4601 for other partition respectively
Program telephone number 1 [ Master Code ] [ 7 ] [ 0611 ] [ 16-digit Number ] [ ] [ ]
Program telephone number 2 [ Master Code ] [ 7 ] [ 0612 ] [ 16-digit Number ] [ ] [ ]
Delete telephone number 3 [ Master Code ] [ 7 ] [ 0613 ] [ # ]
Program System date(DD-MM-YY) [ Installer Code ] [ 7 ] [ 0501 ] [ 6-digits Value ] [ ] [ ]
Program System Time(hour+min) [ Installer Code ] [ 7 ] [ 0502 ] [ 4 digits Value ] [ ] [ ]
Program Auto Daily Test(hour+min) [ Installer Code ] [ 7 ] [ 0503 ] [ 4 digits Value ] [ ] [ ]
*24-hour format
Program Interval Time [ Installer Code ] [ 7 ] [ 0504 ] [ 4 Digits Value ] [ ] [ ]
*set the interval waiting time to report CMS.If the interval time is not set then the test report will follow by auto daily test
Program Auto Away Arm [ Installer Code ] [ 7 ] [ 1531 ] [ 4 Digits Value ] [ ] [ ]
Address 1531 for partition 1 , Address 2531,3531,4531 for other partition respectively
Program Auto Disarm [ Installer Code ] [ 7 ] [ 1532 ] [ 4 Digits Value ] [ ] [ ]
Address 1532 for partition 1 , Address 2532,3532,4532 for other partition respectively
Rename Zone* [ Master Code ] [ 7 ] [ 0170 ] [ 9 Digits max] [ ]
*Address 0170 is Zone 1, Address 0171 to 0185 is for Zone 3 to 16 respectively
*This function is for L16 LCD keypad only
No installer setting [ Master Code ] [ 7 ] [ 0817 ] [ 4 Digits Value ] [ ]
L8_UM1016-v1.0