Review Event Memory
LCD Keypad display
1) Press [ # ] + [ 4 ]
(If Quick Review is enabled)
Or
Press [ User Code ] + [ 4 ] + [ Partition Select ]
☼ The Line light will blink to indicate Review mode.
☼ The Armed light will turn on to indicate events within the latest Arm period.
☼ The Zone light will turn on to indicate any zone triggered.
2) Press [ 4 ] to skip to next set of alarm events of previous Arm period.
☼ The Line light will blink to indicate Review mode.
☼ The Armed light will turn on to indicate events within the previous Arm period.
☼ The Zone light will turn on to indicate any zone triggered.
☼ You can press [ 4 ] repeatedly to view all the events.
♪ The panel will emit a long beep, indicating that you've reached end of events.
3) Press [ 0 ] to clear the event memory.
Or
Press [ ] to exit Review mode.
☼ The Line light will turn off to indicate exit from Review mode.
♪ 3 beeps to indicate exit from Review mode.
Information
● In this mode, the keypad can display all faulted zones, AC failure and low battery events,
emergency events (panic, medical, fire) occurring up to 250 events.
● Control panel can record up to 250 events memory.
● If the system memory is full (250 events), the next new event will overwrite the earliest event, in a
first in-first out basis.
● Event memory will remain in storage until it is cleared by entering digit ‘0’. Power reset and
defaulting of control panel options back to factory setting will not clear the events memory register
● For LED keypad, light indicator shows the event that occurred.
OFF ☼ ON
Event / LEDs A1/A2/A3/A4 15 16
Arm ☼
Disarm
☼ ☼ ☼
L8_UM1016-v1.0