Walk-Test
LCD Keypad display
1) Press [ User Code ] + [ 5 ]
☼ The Line light will blink to indicate Walk-test mode.
2) Trigger all used zones.
☼ The respective zone light will turn on to indicate the zone is tested.
3) Press [ 1 ] to activate siren (toggle ON/OFF)
[ 2 ] to activate strobe light (toggle ON/OFF)
4) Press [ * ] to exit Walk-test mode
☼ The Line light will turn off to indicate exit from Walk-test mode.
Information
● Walk-test allows all zones, siren and strobe to be tested for functionality. Perform Walk-test
periodically to ensure the system is in a working condition.
● Ensure all zones are closed and there is no one within the premises before conducting Walk-test.
● Walk-test mode is not allowed during system Arm.
System Test
LCD Keypad display
Press [ # ] + [ 3 ]
Or
Press [ User Code ] + [ 3 ] + [ Partition Select ]
☼ The Line light turns on to indicate system dialler performing CMS reporting.
Information
● System test sends a test report to CMS if enabled to do so.
● Please inform your installer to activate this function if you wish to perform this operation.