Away Arming
LCD/LED Keypad display
Press [ # ] + [ AWAY ] / [ 9 ] + [ Partition Select ]
(If Quick Away option is enabled)
Or
Press [ User Code ] + [ 9 ]
The partition armed light turns on on LED keypad and arm light turns on on LCD keypad.
Leave the premises within the Exit time. Exit beeping will continue until Exit time expires.
The Line light turns on to indicate system dialler performing CMS reporting.
Information
Away arming will activate all zones of your alarm security system except bypassed zones. All
interior and external perimeters are armed. Use this mode when leaving your premises.
Before arming your system to Away mode, all zones should be closed. There should not be any
movement in the rooms protected by motion detectors and each door or window protected by
reed switches should be properly closed.
Key-switch input is available on the control panel and can be used to toggle between Arm and
Disarm.
If an illegal code is entered to Arm in Away mode, the system responds by a long error beep.
The system cannot Arm while in other operation mode. Press [ ] + [ ] to exit from other
operation mode first.
Options to be Programmed by Installer
No Force Arm:
The system will not be allowed to Arm via keypad if an Instant zone is left open but not if it is
a delay zone. A long error beep is issued to warn you of such situation. If you want Force Arm
function, any zones left opened after arming will be automatically bypassed and are reported
as zone bypass. The system will resume monitoring the zone once it is closed again for the
duration of that armed period.
Force Arm Siren Warning:
The siren will continuously sound or squawk to indicate a Force Arm situation. You should
Disarm the panel, check the premises and then Arm again. Continual warnings could mean
there is a problem with a detection device and that particular zone may have to be manually
bypassed.
Away Squawk:
Siren will output two squawks upon arming the system in Away mode and output a single
squawk when the system is disarmed.
No Arm If Battery Low:
You may not Arm the system if the back-up battery is determined as low and A.C power is not
present.
Exit Beep:
Keypad beeper will beep continuously for the duration of Exit time.
Please consult your installer to enable the above options.