SUPERSERVER 5018D-FN4T User's Manual
6-6
Installing 2.5" Fixed Hard Drives
One to four 2.5" hard drives may be installed in several different congurations.
Refer to Figures 6-3 and Figure 6-5.
Installing Fixed 2.5" Hard Drives
1. Power down the system as described in Section 6-2 and remove the cover.
2. Install the hard drives into the hard drive brackets and secure them to the bracket
with the screws provided.
3. Place the hard drives and brackets into the chassis as illustrated in Figure 6-3
or Figure 6-5. Orient two or more drives with the cable connections facing the
inside of the chassis.
4. Secure the hard drive brackets to the chassis oor by inserting the screws up
through the underside of the chassis.
5. Connect the hard drive wiring.
6. Reinstall the chassis cover and power cord, then power up the server.
Note: Bracket ordering information: for single drive height, MCP-220-00051-0N; for
double drive height, MCP-220-00044-0N.