SuperServer 1019C-HTN2 User's Manual
32
Power Supply Failure
With only one power supply unit in the chassis, power must be completely removed from the
server before removing and replacing the power supply unit.
Removing the Power Supply
If the power is on, removing power from the system as described in Section 3.1.
1. Disconnect all wiring from the power supply.
2. Remove the four screws which hold the power supply in the chassis. The two rear
mounting screws are located at the rear of the chassis. The two mid-chassis mounting
screws are accessed from the underside and extend upwards through the chassis. Set
the screws aside for later use.
3. Remove the power supply from the chassis.
Installing a Power Supply
1. Replace the failed power supply with another identical power supply module.
2. Align the mounting thru holes on the power supply with the mounting holes in the
chassis and reattach the power supply to the chassis using the four screws which were
previously set aside.
3. Connect the chassis wiring to the power supply.
4. Reattach the AC power cord and power on the system.