EasyManua.ls Logo

Supermicro SuperServer SYS-221BT-DNTR - Creating Nvme RAID Configurations

Supermicro SuperServer SYS-221BT-DNTR
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
Chapter 6: Optional Components
Creating NVMe RAID Congurations
1. Open Advanced > Intel(R) Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume.
2. Set Name.
3. Set RAID Level.
4. If cross-controller RAID is required, select Enable RAID spanned over VMD
Controller.
5. Select specic disks for RAID with an [X].
RAID0: Select at least two [2 - 24] disks
RAID1: Select only two disks
RAID5: Select at least three [3 - 24] disks
RAID10: Select only four disks
6. Select Strip Size (Default 64KB).
7. Select Create Volume.
8. If another RAID is needed, start again at step 1.
Figure 6-8. Created Volume without
enabling RAID spanned over VMD
controller
Figure 6-9. Created Volume with enabling
RAID spanned over VMD controller

Table of Contents