Chapter 4: AMI BIOS
4-43
VR Voltage Limit
This feature sets the Voltage Regulator voltage limit. The value is
represented in mV. A value of 1250 equals 1.25V. Set this number to
0 for Auto. This uses the BIOS VR mailbox command 0x6.
TDC Enable
Enable or Disables TDC (Thermal Design Current). The options are
Enabled and Disabled.
TDC Current Limit
The TDC Current Limit is dened in 1/8A (Amperes) increments and
uses the BIOS mailbox command 0x1A. A value of 1000 equals 125A.
Range is 0-32767. Enter 0 for 0 Amps.
TDC Time Window
The TDC Time Window is dened in milliseconds. Range is 1-8ms and
10ms. Note that 9ms has no valid encoding in the MSR denition. The
options are 1ms, 2ms, 3ms, 4ms, 5ms, 6ms, 7ms, 8ms, and 10ms.
TDC Lock
Enable or Disables TDC Lock. The options are Enabled and Disabled.
GT-Sliced VR Settings
GT-Sliced Domain
VR Cong Enable
Select Enable to activate VR conguration options. The options are
Enabled and Disabled.
AC Loadline
AC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.
DC Loadline
DC Loadline is dened in 1/100 mOhms and uses the BIOS mailbox
command 0x2. A value of 100 equals 1.0 mOhm, and 1255 is 12.55
mOhms. Range is 0-6249 (0-62.49 mOhms). Enter 0 for AUTO.

Table of Contents