Warning Explanation
Depth Depth exceeds your depth alarm limit
Dive time Dive time exceeds your dive time alarm limit
Diluent high pO₂ Diluent partial pressure of oxygen exceeds safe level
(>1.6); no immediate danger unless diluent is used, e.g.
diluent flush
Diluent low pO₂ Diluent partial pressure of oxygen below safe level
(<0.18); no immediate danger unless diluent is used, e.g.
diluent flush
Gas time Gas time is below the gas time alarm limit you set, or
tank pressure is below 35 bar (~510 psi), in which case
gas time is zero.
Safety stop broken Ceiling of the voluntary safety stop broken by more than
0.6 m (2 ft)
Tank pressure Tank pressure is below your tank pressure alarm limit.
There is a built in 50-bar alarm that cannot be changed.
In addition to it there is a configurable tank pressure
alarm, you can set to any value between 10-360 bar
(145-5221 psi) and your dive computer also shows an
alarm when that value and 50 bar (725 psi) pressures
are reached. The tank pressure number is forced onto
the display and turns yellow after the value you set and
red after 50 bar (725 psi).
Notifications indicate events that require preventive actions. Acknowledge the notification by
pressing any button.
Notification
Explanation
CNS 80% Central Nervous System (CNS) Oxygen Toxicity level at
80% limit
OTU 250 Approximately 80% of recommended daily limit for
Oxygen Tolerance Unit/Oxygen Toxicity Unit (OTU)
reached
Change gas On multi-gas dive when ascending, it is safe to switch to
next available gas for optimum decompression profile
Battery low Approximately three hours of dive time left
Recharge needed Approximately two hours of battery time left; re-charging
required before next dive