FB-09
Door open/close times Default 0 Min. Unit 1
Setting Range 0~20
This function code sets the door open and close times after the FB-06/FB-08 setting time.
When lift on-off door times is over this setting value, lift will warn E48 error or E49 error.
If FB-09 = 0, door on-off protection is invalidation. The system will not stop opening/closing
door until it receives door open/close limit signal.
FB-10
Running main oor door state Default 0 Min. Unit 1
Setting Range 0~1
FB-10 is the function for lift waiting when the main oor door opens.
0: open the door normally
1: door open waiting
FB-11
Time keeping for external call to
open door
Default 5s Min. Unit 1s
Setting Range 1~30s (corresponding to external call)
It’s the length of time waiting when there’s external call command but no operation
box command. If there’s closing door command inputting, it responds to the command
immediately.
FB-12
Time keeping for internal call to
open door
Default 3s Min. Unit 1s
Setting Range 1~30s (corresponding to internal call command)
It’s the length of time waiting when there’s operation box command. If there’s closing door
command inputting, it responds to the command immediately.
FB-13
Time keeping for main oor to open
door
Default 10s Min. Unit 1s
Setting Range 1~30s
It’s the length of time waiting when the lift runs to the main floor. If there’s closing door
command inputting, it responds to the command immediately.
FB-14
Time keeping for door open
delaying
Default 30s Min. Unit 1s
Setting Range 10~1000s
It’s the time for keeping the door open when there’s door open delaying signal inputting. If
there’s door close signal inputting, it responds to close the door immediately when the door
open signal disappears.