Function code Name Setting Range Min. Unit Default
FE-01 Floor 1 corresponding display
0000~1999
1 1901
FE-02 Floor 2 corresponding display 1 1902
FE-03 Floor 3 corresponding display 1 1903
FE-04 Floor 4 corresponding display 1 1904
FE-05 Floor 5 corresponding display 1 1905
FE-06 Floor 6 corresponding display 1 1906
FE-07 Floor 7 corresponding display 1 1907
FE-08 Floor 8 corresponding display 1 1908
FE-09 Floor 9 corresponding displa
y 1 1909
FE-10 Floor 10 corresponding display 1 0100
FE-11 Floor 11 corresponding display 1 0101
FE-12 Floor 12 corresponding display 1 0102
FE-13 Floor 13 corresponding display 1 0103
FE-14 Floor 14 corresponding display 1 0104
FE-15 Floor 15 corresponding display 1 0105
FE-16 Floor 16 corresponding display 1 0106
FE-17 Floor 17 corresponding display 1 0107
FE-18 Floor 18 corresponding display 1 0108
FE-19 Floor 19 corresponding displa
y 1 0109
FE-20 Floor 20 corresponding display 1 0200
FE-21 Floor 21 corresponding display 1 0201
FE-22 Floor 22 corresponding display 1 0202
FE-23 Floor 23 corresponding display 1 0203
FE-24 Floor 24 corresponding display 1 0204
FE-25 Floor 25 corresponding display 1 0205
FE-26 Floor 26 corresponding display 1 0206
FE-27 Floor 27 corresponding display 1 0207
FE-28 Floor 28 corresponding display 1 0208
FE-29 Floor 29 corresponding displa
y 1 0209
FE-30 Floor 30 corresponding display 1 0300
FE-31
Floor 31 corresponding display
(double door plural selection hall
call setting)
1 0301
This group function code can set hall displaying content of the opposite oor. Its value is made
up of 4 bit. The higher 2 bit express the tens digit of oor displaying, and the lower 2 bit express
the first rank of oor displaying. The higher 2 bit’s and lower 2 bit
’s meaning are as follows: