NICE3000 User Manual Function parameter description
149
Binary bit Function Binary setting Binary bit Function Binary setting
Bit2
No output door
closing signal
when running
0 Bit10
Weighing analogue
input uses 10 bit AD
sampling
1
Bit3
Door close
Maintenance
detect door close
limit
0 Bit11
No door closing
command after
light-off in the car
1
Bit4
Contactor
conglutination
recover
automatically
0 Bit12
No stopping
function selection
in the Reversal
leveling of no
service oor
0
Bit5
Force reducer
switch
conglutination
inspection
0 Bit13
Fast speed lifts
protection function
selection
0
Bit6
Synchronous
motor enclosed
star contactor
outputs when it
stops
0 Bit14
No direction display
when theres no
call after the lift
stops
0
Bit7 Reserved 0 Bit15
Open-through door
separately control
1
In order to make it convenient for lift factories to do the value added setting, several functions
of NI
CE 3000 is chosen through FE-32, FE-33.The functions mentioned above are described
as follows:
Motorman: There will be no motorman function if theres selection.
Fire return to main oor: After this selection, use can get into the re return to the main oor
function through the floor display panel or main control panel terminal (fire signal). In this
condition, the lift will stop at the nearest oo
r without opening the door if its running at that
moment. Then, if theres reman signal inputting, the lift will get into reman running.
Re-leveling: The car load is changing dramatically when then car door opens, it will cause
the car cage of high oor lift or heavy load lift higher or lower than the sill. After choosing this
function, the lift will re-leveling run with quite low speed when the
door is open. The function
requires the cooperation of the external enclosed door contactor, and it needs three leveling
contactors (up, down leveling, door zone).
Pre-opening: When the lift is running normally, the speed is slower than 0.1m/s in the stopping
course, and the door zone signal is valid, it jumps out the door lock signal through envelop door
contactor, and pre-opens the door to make
the most efciency.
Hall call conglutination disposal: Generally, if the hall call button is conglutination, it may cause
the lift repeating opening the door in the current oor. After using this function, Nice 3000 can
identify the information of the hall call button automatically. If any abnormal is found, it will
disposal the button in self-motion, so it wont affect the using of the lift.
Night
security floor, down collective selective fastigium service, fastigium service and time-
sharing service oor function: refer to the parameter introduction in F6 group.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-GCB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-GCB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-GCB-A
CategoryController
LanguageEnglish

Related product manuals