Brake output pre-run output
For special asynchronous master machine use, special treatment for time sequence; invalid for
sync machine.
Independent running: It’s not in parallel (group control), and it gets into the independent
running condition through the independent running switch in the car cage. At the moment, the
lift doesn’t respond to the hall call and the door operation is the same with th
at in motorman
condition, which means there’s no automatic door closing and it opens the door automatically
if it fails to complete closing the door. If it’s in the parallel (group control) state, the system will
get off the parallel (group control) in self-motion.
Maintenance automatic close door: When the machine room is in the maintenance operation,
if the car cage’s door isn’t closed, it will c
ause the lift’s door lock block and the lift
can’t travel. If choose this function, press UP and DOWN button, the lift will close the door
automatically when it’s in maintenance. There’s no close door signal outputting if you don’t
press UP and DOWN button.
Car call miss delete: If you are ready to delete the registered car call command, press the call
button twice continuously (interval time aroun
d 0.5s), the system will cancel this call. However,
if the car call has been locked by the lift, you can’t delete this call command.
Hall call miss delete: If you are ready to delete the registered hall call command, press the call
button twice continuously (interval time around 0.5s), the system will cancel this call.
Emergency auto-running car: While it uses permanent-magnet synchronous motor, the
lift can
fulfill auto-running car through the enclosed star contactor when there’s power failure and
it opens the door when it slides to the leveling position. This function enables the economical
emergency rescue realize.
Emergency auto-rescue overtime protection: If the car cage is in balance load or the rescue
driving power’s capacity is not adequate, it will cause long emergency rescue time and
even
dangers occur. This function enables to stop rescuing when auto-running car rescue time is
over 100s, and rescue driving time is over 50s.
Door lock jump-out test: If door lock jump-out is found after door open limit, the system alarms
E53 when the lift is running in normal condition.
Door opening limit keep open: If choose this function, the lift keep outputting open door signal
when there’s
door opening limit.
No output door closing signal when running: If choose this function, the lift doesn’t output
close door signal when it is running.
Door close maintenance detects door close limit: If choose this function, the system can judge
the door close limit signal in the door close maintenance function. If not, the system can only
judge the door close limit situation through door lock signa
l.
Contactor conglutination recover automatically: Detect the brake, and traveling contactors’
feedback contacts, alarm E36, E37 if the contacts are deviant, and it can’t recover
automatically. If the two errors occur, this function enables to recover automatically no more
than three times as long as these errors disappear.
Force reducer switch conglutination inspection: This function enables to mon
itor the force