Function
Code
Name Setting Range Min. Unit Default
Modifi-
cation
F5-25
Car top board
input type
selection
0~255 1 64 ★
F5-26
Select function
of terminal Y1
0:No function
1:Run contactor output
2:Brake contactor output
3:advanced door-opening module output
4:Fire arrival landing signal feedback
5:Door motor 1 open
6:Door motor 1 close
7:Door motor 2 open.
8:Door motor 2 close
9:Brake, run contactor normal
10:Failure state
11:Run monitor
12:Synchronous motor U,V,W jump-out
output
13:Power failure emergency running
switching automatically
14:System normal
15: Emergency buzzer output
16: Brake forced output
17: elevator up running mark
18: illustration and fan output
1 1 ★
F5-27
Select function
of terminal Y2
1 2 ★
F5-28
Select function
of terminal Y3
1 3 ★
F5-29
Select function
of terminal Y4
1 4 ★
F5-30
Select function
of terminal Y5
1 0 ★
F5-
31
Select function
of terminal Y6
1 0 ★
F5-32
Communication
state display
Bit 0-bit11 hall call communication state
Bit12-bit15 inside call communication state
●
F5-33
Program control
select
Bit 4: cancel the arrival gong at night
Bit 5: input function 25/57 for the mmotor
overheat input or earthquake detection
Bit 6: add 1 more time doo-lock break when
the inspection to normal
Bit 7: no error display on the
small keypad
Bit 8: remove the door-open call when door-
open limit
Bit 9: elevator stop when the brake feedback
is abnormal
1 0
F5-34
Terminal state
display
●
F5-36
Weighing input
selection
0:car top panel input and analogue input is
invalid
1:Car top panel switch input
2:Car top panel analog input
3:Main control panel analog sampling.
1 2 ★
F6 Lift Basic Parameters
F6-00
The highest
landing
F6-01~31 1 9 ★
F6-01
The lowes
t
landing
1~F6-00 1 1 ★
F6-02
Parking main
landing
F6-01~ F6-00 1 1 ★
F6-03
Fire main
landing
F6-01~F6-00 1 1 ★
F6-04
Lift lock main
landing
F6-01~F6-00 1 1 ★
F6-05 service oor 1 0~65535 (from 1st to 16th oor) 1 65535 ★
F6-06 service oor 2 0~65535 (from 17th to 31st oor) 1 65535 ★
F6-07
Group control
number
1~8 1 1 ★
F6-08 Lift number 1~8 1 1 ★