NICE3000 User Manual Function parameters tables
91
Function
Code
Name Setting Range Min. Unit Default
Modi-
cation
F6-09
Parallel
selection
Bit0:separate stay function
Bit1: reserved
Bit2:Parallel in monitor contactor
1 0
F6-10
Leveling sensor
delay time
10~50ms 1 14ms
F6-11
Elevator
function
selection
Bit4: stop 300 ms current bias mode
Bit5:synchronous motor startup current detect
function
Bit7: inspection non-door zone opening is valid
Bit8: rst power-apply, open
for once when it is
normal
Bit10: reversal-leveling buzzer is not sound
Bit13: E53 error auto reset
1 0
F6-12 VIP oor 0- highest oor (F6-00) 1 0
F6-13 Security oor F6-01~F6-00 1 1
F6-14
down-collective
1 start time
00.0023.59(hr.min.) 00.01 00.00
F6-15
down-collective
1 end time
00.0023.59(hr.min.) 00.01 00.00
F6-16
down-collective
2 start time
00.0023.59(hr.min.) 00.01 00.00
F6-17
down-collective
2 end tim
e
00.0023.59(hr.min.) 00.01 00.00
F6-18
Time-sharing
service 1 start
00.0023.59(hr.min.) 00.01 00.00
F6-19
Time-sharing
service 1 end
00.0023.59(hr.min.) 00.01 00.00
F6-20
Time-sharing
service 1 oor 1
065535 (from 1st to 16th oor) 1 65535
F6-21
Time-sharing
service 1 oor 2
065535 (from 17th to 31 st oor) 1 65535
F6-22
Time-sharing
service 2 start
00.0023.59(hr.min.) 00.01 00.00
F6-23
Time-sharing
service 2
end
00.0023.59(hr.min.) 00.01 00.00
F6-24
Time-sharing
service 2 oor 1
065535 (from 1st to 16th oor) 1 65535
F6-25
Time-sharing
service 2 oor 2
065535 (from 17th to 31 st oor) 1 65535
F6-26
Parallel
fastigium 1 start
time
00.0023.59(hr.min.) 00.01 00.00
F6-27
Parallel
fastigium 1 end
time
00.0023.59(hr.min.) 00.01 00.00
F6-28
Parallel
fastigium oor 1
F6-01~F6-00 1 1
F6-29
Parallel
fastigium 2 start
time
00.0
023.59(hr.min.) 00.01 00.00
F6-30
Parallel
fastigium 2 end
time
00.0023.59(hr.min.) 00.01 00.00
F6-31
Parallel
fastigium oor 2
F6-01~F6-00 1 1
F7 Testing Function Parameters
F7-00 Test oor 1 0the highest oor (F6-00) 1 0