Function parameters tables NICE3000 User Manual
92
Function
Code
Name Setting Range Min. Unit Default
Modi-
cation
F7-01 Test oor 2 0the highest oor (F6-00) 1 0
F7-02 Test oor 3 0the highest oor (F6-00) 1 0
F7-03
Test times at
random
060000 1 0
F7-04
Landing call
enable
0Landing call allowable;
1Landing call forbidden
1 0
F7-05
Door open
enable
0Door open allow
1Door open forbidden
1 0
F7-06
Overload
function
selection
0Overload run forbidden
1Overload run allowab
le
1 0
F7-07 Limit enable
0End switch availability;
1End switch invalidation
1 0
F8 Reinforce Function Parameters
F8-00
Weighing auto-
tuning
0100% 1% 0%
F8-01
Pre-torque
selection
0Pre-torque is invalid
1weighing pre-torque compensation
2: automatic pre-torque compensation
1 0
F8-02
Pre-torque bias,
Zero servo
current
coefcient
0.0100.0%
0.20%~50.0%
0.1%
50.0%
15.0%
F8-03
Drive gain,
Zero servo
speed loop KP
0.00
2.00
0.00~1.00
0.01
0.60
0.50
F8-04
Brake gain
Zero servo
speed loop TI
0.002.00
0.00~2.00
0.01
0.60
0.60
F8-05
Car load at
present
01023 1 0
F8-06 Car no load set 01023 1 0
F8-07 Car full load set 01023 1 100
F8-08
Anti-nuisance
function
0This function is forbidden;
1Allowable (This function can be used with
weighing sensor available.)
1 0
F8-09
Power failure
emergency
rescue speed
0.000~0.100m/s 0.001m/s 0.050m/s
F8-10
Po
wer failure
emergency
rescue
selection
0: no running
1: UPS power running
2: 48V battery power
1 0
F8-11
Stopping torque
output delay
0.200~1.500s 0.001 0.200
F9 Time Parameters
F9-00
Free return
main oor time
0240min 1min 10min
F9-01
Fan and light
closed time
0240min 1min 2min
F9-02
Longest interval
time of oor
running
045s (invalidation under 3s) 1s 45s
F9-03 Clock: year 20002100 1
Current
time