Function
Code
Name Setting Range Min. Unit Default
Modifi-
cation
F7-01 Test oor 2 0~the highest oor (F6-00) 1 0 ☆
F7-02 Test oor 3 0~the highest oor (F6-00) 1 0 ☆
F7-03
Test times at
random
0~60000 1 0 ☆
F7-04
Landing call
enable
0:Landing call allowable;
1:Landing call forbidden
1 0 ☆
F7-05
Door open
enable
0:Door open allow
1:Door open forbidden
1 0 ☆
F7-06
Overload
function
selection
0:Overload run forbidden
1:Overload run allowab
le
1 0 ☆
F7-07 Limit enable
0:End switch availability;
1:End switch invalidation
1 0 ☆
F8 Reinforce Function Parameters
F8-00
Weighing auto-
tuning
0~100% 1% 0% ★
F8-01
Pre-torque
selection
0:Pre-torque is invalid
1:weighing pre-torque compensation
2: automatic pre-torque compensation
1 0 ★
F8-02
Pre-torque bias,
Zero servo
current
coefficient
0.0~100.0%
0.20%~50.0%
0.1%
50.0%
15.0%
★
F8-03
Drive gain,
Zero servo
speed loop KP
0.00~
2.00
0.00~1.00
0.01
0.60
0.50
★
F8-04
Brake gain
Zero servo
speed loop TI
0.00~2.00
0.00~2.00
0.01
0.60
0.60
★
F8-05
Car load at
present
0~1023 1 0 ●
F8-06 Car no load set 0~1023 1 0 ★
F8-07 Car full load set 0~1023 1 100 ★
F8-08
Anti-nuisance
function
0:This function is forbidden;
1:Allowable (This function can be used with
weighing sensor available.)
1 0 ☆
F8-09
Power failure
emergency
rescue speed
0.000~0.100m/s 0.001m/s 0.050m/s ☆
F8-10
Po
wer failure
emergency
rescue
selection
0: no running
1: UPS power running
2: 48V battery power
1 0 ☆
F8-11
Stopping torque
output delay
0.200~1.500s 0.001 0.200 ☆
F9 Time Parameters
F9-00
Free return
main oor time
0~240min 1min 10min ☆
F9-01
Fan and light
closed time
0~240min 1min 2min ☆
F9-02
Longest interval
time of oor
running
0~45s (invalidation under 3s) 1s 45s ★
F9-03 Clock: year 2000~2100 1
Current
time
☆