ELECTRICAL
6-8
mA
INSPECTION
BATTERY LEAK CURRENT INSPECTION
Remove the left side cover .
Turn the ignition switch to the OFF position.
Disconnect the battery lead wire.
Measure voltage between the battery - terminal and the
specified ground cable terminal If the reading exceeds
the specified value then leakage is present
.
,.
09900-25008: Pocket tester
Battery leakage: Less than 10 µA
Tester knob indication: ( -----, 200µA)
Because the leak current might be large turn the
tester to high range first when connecting an
ammeter
Do not turn the ignition switch to the ON position
when measuring current.
,
.
GENERATOR COIL INSPECTION
Remove the right side cover.
Disconnect generator coupler .
Measure the resistence between the lead wires, if the
resistence is incorrect, replace the generator coil.
09900-25008: Pocket tester
Generator coil resistance: 0.9 (Y-Y)Ω
Tester knob indication: Resistance
Faulty regulator/rectifier.
Short circuit of wiring harness.
Poor contact of couplers.
Inspect regulator/rectifier.
Inspect wirings,
Correct
Incorrect
Incorrect
Faulty battery.
Others
Battery overcharge
Faulty regulator/rectifier.
Faulty battery.
Poor contact of generator
lead wire coupler.
Correct
()Continue the last page
CAUTION
1