Equipment details
74
• Shut off the gas cylinder.
• Open the windows.
• Do not actuate any electrical switches.
• Have the entire system checked by an expert.
1. Repairs may only be carried out by an expert.
2. The following will invalidate the guarantee:
a) Any alteration to the appliance.
including the cowl.
b) The use of non-original Truma
parts/accessories.
c) Non-observance of the
Operating Instructions.
3. The operating pressure for the gas supply
is 30 mbar and must correspond to the
operating pressure of the appliance (see
data plate).
Liquid gas systems must comply with the
technical and administrative regulations of
the respective country of use (e.g. EN 1949
for vehicles in Europe).
A qualified technician must inspect/test
according to EN 1949 every two years and a
certificate issued.
The vehicle owner is always responsible for
arranging the inspection.
4. Do not operate the water heater when
refuelling the vehicle and when in the garage.
5. During the initial operation of a brand new
appliance (or after it has not been used for
some time), a slight amount of fumes and
a certain smell may be noticed for a short
while. Remedial action is to immediately
run the heater at maximum output and to
ensure adequate room ventilation.
6. If the burner makes an unusual noise or if the
flame lifts off, it is likely that the regulator is
faulty and it is essential to have it checked.
Technical data
Water contents: 10 Iitres
Water pressure: up to max. 2.8 bar
Type of gas: Liquid gas (propane/butane)
Operating pressure: 30 m/b
Rated thermal output: 1500 W
Gas consumption: 120 g/h
Heating time up to approx. 70ºC:
Gas operation: approx. 35 minutes
Electrical operation: approx. 70 minutes
Gas and electrical operation: approx 20 minutes.
Power consumption 12 V
Ignition: 0.17 A
Heating up: 0.08 A
Standby: 0.04 A
Power consumption 230 V
Heating up: (2 A) 450 W
Weight (empty): Approx: 6.7 kg