TRUMA ULTRAHEAT ADDITIONAL
ELECTRIC HEATING
For Trumatic S 3002 heaters
Function description
Truma-Ultraheat is an additional 230V electric
heater for the LPG heater models Trumatic
S 3002/S 5002. Heater operation is basically
possible with gas only, electricity only or
simultaneously with electricity and gas.
When using simultaneously the electrical unit
will switch itself off before overheating occurs
as a result of the stronger gas burner.
When using electrical only we recommend to
set the fan control on position 3 (manual or
auto), remembering to set the output level to
2000W (ensure that the fuse protection for the
power supply of the camp site is sufficient).
If more than 2kw are required (heating up/cold
temperatures) you must refer back using gas
operations as the 230V electrical operation is a
secondary heater only.
The electric heater can also be operated
without the Trumavent fans.
WARNING: Due to the design, the heater
front case will become hot during
operation. The operator is obliged to
ensure that due care is taken to protect
third parties (small children in particular).
Operating instructions
Before operating the heater for the first
time it is essential to observe the operating
instructions, enclosed with the heater.
Control panel with thermostat
a = Rotary switch “Off”
b = Rotary switch “On”
power settings:
500 - 1000 - 2000 W
c = Rotary control knob for room
temperature (illuminated by green
indicator lamp “operation”)
Switching On
Attention: Before switching on, ensure that
the fuse protection for the power supply of the
campsite is sufficient for the selected power
setting (b) (see Technical Data).
Important: The electric feed line for the caravan
must be fully unwound from the cable drum.
1. To switch on, turn the rotary switch to the
desired output level (b).
2. Set rotary control knob (c) to the desired
room temperature.
The thermostat setting on the operating
element (1-9) must be determined individually
depending on the heating requirement and
the type of vehicle. For an average room
temperature of about 23°C, we recommend a
thermostat setting of about 6 - 8.
Switching off
Switch the heating system off at the rotary
switch (a).
Important operating notes
1. Repairs may only be carried out by
an expert.
2. The heater’s hot air outlet should under
no circumstances be blocked. Never
hang clothes or similar in front of or on
top of the heater to dry. This could cause
serious damage to the heater as a result
of overheating. Do not place inflammable
materials near the heater! Please observe
these instructions for your own safety.
3. The performance of the room thermostat
will be affected if temporarily covered
or obstructed