Equipment details
87
Overheating protection 230 V
The 230 V heating facility has a mechanical
overheating switch. If the 12 V power supply
is interrupted during operation or during the
after-run period, for example, the temperatures
within the unit could activate the overheating
protection.
To reset the overheating protection, allow
heater to cool, remove connection cover and
press red reset button.
Disposal
The liquid gas heater must be disposed in
accordance with the administrative stipulations
of the respective country in which it is used.
National regulations and laws (in Germany, for
example, the Altfahrzeug-Verordnung – old
vehicle directive –) must be observed.
In other countries, the relevant regulations must
be observed.
Technical data
determined in accordance with EN 624 or
Truma test
Device category
I
3
B/P
in accordance with EN 437
Type of gas: Liquid gas (propane / butane)
Operating pressure: 30 mbar (see type plate)
Water contents: 10 litres
Heating up time from approx. 15° C to
approx. 60° C
Boiler approx. 20 minutes (measured according
to EN 15033) Heater + boiler approx. 80 min.
Water pressure: max. 2.8 bar
Rated thermal output
(automatic output levels)
Combi 4 E: 2000 W / 4000 W
Combi 6 E: 2000 W / 4000 W / 6000 W
Electrical operation
Combi 4 E / Combi 6 E: 900 W / 1800 W
Mixed operation (gas and electrical)
Combi 4 E: max. 3800 W
Combi 6 E: max. 5800 W
Gas consumption
Combi 4 E: 160 – 320 g/h
Combi 6 E: 160 – 480 g/h
Readiness-heat power requirement
Combi 4 E / Combi 6 E:
Gas operation 5.2 g/h
Air delivery volume (free-blowing without
hot-air pipe)
Combi 4 E: with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Combi 6 E: with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Combi 4 E: Short-term max. 5.6 A
(average power consumption 1.1 A)
Combi 6 E: Short-term max. 5.6 A
(average power consumption 1.3 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional):
maximum 0.4 A
Current input of 230 V
3.9 A (900 W) or 7.8 A (1800 W)