EasyManua.ls Logo

Symmetricom TimeProvider 1100 - Page 162

Symmetricom TimeProvider 1100
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
162 TimeProvider User’s Guide 097-58001-02 Revision C – August 2005
SYS Events
CLRDELAY Time, in seconds,
before a faulted
signal indicates it is
valid as a system
reference
EQPT 5 s 0 to 1000 s
ELEVTIME Indicates that Alarm
elevation time (1440
min.) is enabled or
disabled
EQPT DISABLE ENABLE | DISABLE
FACTORY Indicates that the unit
has been reset to
Factory default. All
modules installed in
the system are reset
EQPT n/a n/a
FLTDELAY Time, in seconds,
before faulted signal
indicates it is not
valid as a system
reference
EQPT 10 s 1 to 15 s
FREEFLT Indicates if the
Output Fault is issued
when the local
oscillator enters
Free-Run mode.
EQPT SQUELCH ON – In fault mode,
generate outputs based on
system SSM
AIS – In fault mode,
generate AIS outputs
SQUELCH – In fault mode,
outputs are turned off
HOLDFLT Indicates if the
Output Fault is issued
when the local
oscillator enters
Holdover mode
EQPT ON ON – In fault mode,
generate outputs based on
system SSM
AIS – In fault mode,
generate AIS outputs
SQUELCH – In fault mode,
outputs are turned off
INPREF Indicates if the
system automatically
selects another
reference input.
Operator has
enabled the selected
reference input
(REFMODE must be
set to FORCED)
T1 PRS PRS – PRS input is
selected as reference
INP1 – INP1 is selected as
reference
INP2 – INP2 is selected as
reference
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values

Table of Contents

Other manuals for Symmetricom TimeProvider 1100

Related product manuals