11
PLUMBING REQUIREMENTS
This equipment must be installed to comply with the applicable federal, state or local plumbing codes.
WATER TREATMENT IS REQUIRED TO PRESERVE THE FULL MACHINE WARRANTY. Please ensure that the
incoming water complies with the warranty requirements listed on page 7.
Using the provided stainless steel braided hose, connect the pump to the shuto valve on the ltered cold
water line. Fings on the hoses and pumps are 3/8” tube compression. Thread sealant or Teon tape is
not necessary. Make connecons snug, but do not over ghten.
Turn incoming water ON and check for leaks.
Synesso™machines require a minimum of 50 PSI (3.5 bar) of line pressure at 30gal (120L) per hour to have
the auto-ll system for the steam tank funconing properly. Please ensure that the incoming water meets
this requirement or contact Synesso™for alternave methods of boosng water pressure.
NOTE: Synesso™sells a “Euro-hose” adaptor hose and ng (part number is 1.5020) which converts from a
3/8” tube ng to a pipe ng, suitable for most non-US plumbing. Please refer to the picture below to
idenfy the dierences between the standard and Euro-style ngs and hoses.
1/4” NPT
3/8” Tube Compression
3/8” BSP Pipe
Standard Fing - #1.5620
Standard Hoses -
48” #1.5060
84” #1.5070
Euro Hose - #1.5010
Euro Fing - #1.5000