65
Category Symptom Possible Reasons & Soluons
Brew
Temperature
Brew Temperature
Reads Low
(error: BRUT0#)
Be sure to allow 20 - 40 minutes from the me the machine is pow-
ered up as the temperatures need to stabilize. Ambient temperature
and airow can change how quickly the machine reaches stability.
Check that the element breaker is in the ON posion
Check that the fuse on the power board, as well as the relay, are
both funconing properly
Check that the brew tank thermal overload switch has not been
tripped
Check that the connecon to the temperature probe is intact and
secure
Make sure the set point has not been changed
Brew Temperature
Reads High
(error: BROT0#)
Display temperature will climb during brewing as hot water from the
steam tank heat exchanger enters the brew tank. This is normal, and
the water dispensed will be at your set point, not the displayed tem-
perature
Make sure the set point has not been changed
Check that the relay is funconing properly
Brew tank may be leaking. Check brew valve and ngs
Steam
Pressure
Steam Pressure is
set for 1.8 Bar or
Higher
The machine can be set for steam pressure at over 2.0 Bar but there
can be side eects in the brewing process. A small amount of water
is preheated in the steam tank for brewing. If the temperature in the
steam tank is set very high then this could allow for the preheated
brew water to be too hot and cause some errac brew temperature
spikes. There are ways to make this work if it is absolutely necessary
to have a very hot steam tank. Contact Synesso™for more info.
Sudden loss of
Steam Pressure
Too much hot water has been used for Tea, Americano, rinsing, or
warming cups while sll steaming milk. Allow the machine to recov-
er. Check temperature seng on the steam tank to make sure they
are high enough for your applicaon. Watch steam gauge, when
pressure drops, allow the heang elements to heat the cold water
being introduced into the steam tank
Check to make sure all Set points, especially steam tank sengs, are
accurate and funconing
Check that the element breaker on the electrical box is in the ON
posion
Steam Tank is not
lling
(error: STFP01)
Check for STFV01 error, which indicates the tank has been lling for
over 5 minutes. If so, power cycle machine, check inlet hoses for
kinks/pinches, check lter
Debris caught in the water control valve or worn out valve