Parameter
Cooling Specifications (cont.)
5, 6
Model 48-5 (Water-cooled)
Maximum Heat Load, laser.......................... 800 W
Minimum Flow Rate .................................... 1.5 GPM, < 60 PSI
Coolant Temperature .................................. 18 °C to 22 °C
Environmental Specifications
Operating Temperature
7
............................. 15 °C to 40 °C
Humidity ...................................................... 0& to 95%, non-condensing
Physical Specifications
48-1
Length ................................................... 16.9 in (42.9 cm)
(incl. cooling tubes) .............................. 18.1 in (46.0 cm)
Width .................................................... 2.8 in (7.1 cm)
Height ................................................... 4.2 in (10.7 cm)
Weight ................................................... 9.0 lbs (4.1 kg)
48-2
Length ................................................... 31.9 in (81.0 cm)
(incl. cooling tubes) .............................. 33.1 in (84.1 cm)
Width .................................................... 2.8 in (7.1 cm)
Height ................................................... 4.2 in (10.7 cm)
Weight ................................................... 18.0 lbs (8.2 kg)
48-5
Length ................................................... 34.9 in (88.6 cm)
(incl. cooling tubes) .............................. 36.4 in (92.5 cm)
Width .................................................... 5.3 in (13.5 cm)
Height ................................................... 4.5 in (11.4 cm)
Weight ................................................... 44.0 lbs (20.0 kg)
* Specifications subject to change without notice.
1 This power level is guaranteed for 12 months regardless of operating hours.
2 Minimum 30 VDC input voltage to obtain guaranteed output power.
3 From cold start (guaranteed).
4 FCC and CE tested at 5 kHz.
5 Lasers with output power > 50 W must be water-cooled. Lasers with output < 50 W can be either water- or air-cooled
depending on their duty cycle. For duty cycles > 50%, water-cooling is strongly recommended. Note that water-cooling
improves power stability at any duty cycle.
6 Inlet cooling water temperature should always be maintained above the dew point to avoid condensation and water damage
to the laser.
7 Published specifications guaranteed at a cooling temperature of 22 °C.