Device Functions
© SYS TEC electronic GmbH 2007 L-1032e_9 37
Example output for the configuration of example 3:
/if/can0 >fin
Usage: fin
if-id: 1
Current filter:
-lds 180 57f
-lde 180 57f
-lds 700 700
-lde 700 700
default: +l
/if/can0 >
Note:
The CAN identifier is given in hexadecimal format, without indication
of a preceding 0x or a subsequent h.