Device Functions
© SYS TEC electronic GmbH 2007 L-1032e_9 39
4.4.2 Data Storage in EEPROM
There is an EEPROM available for storage of the configuration data.
All files that are to be stored as non-volatile data must be located in
the
/save directory. To store files in the EEPROM, the process must
be started manually by the user with a call of the
sync command
(refer to section
4.5.8).
The files in the
/save directory can be modified by the user. The most
important file in this directory is the configuration script
rc. This file
is executed when the firmware is started (under the condition that the
switch "DEFT" = OFF) and contains all of the configuration data for
the CAN-Ethernet Gateway (refer to section
5.3).