62 Functional Description TB8100 Installation and Operation Manual
© Tait Electronics Limited June 2005
detects activity and determines that the signal is valid (or the Tx key line is
activated), it reverts to Normal mode. Otherwise, the timer continues
running.
When the timer reaches the value for Deep Sleep mode, the base station
enters Deep Sleep mode.
If the base station is running on AC power, the timer operates as usual.
However, the base station will continue to run in Normal mode, as
configured in the Service Kit, even after reaching the value for Sleep or
Deep Sleep mode. It only enters these modes after it has changed over to
DC power. If it changes back to AC power, it returns to Normal mode.
4.8.3 Overview of Operation
The following tables show the receiver cycling times and Tx keyup times
available for Normal, Sleep, and Deep Sleep modes and the power saving
measures they correspond to. For more details on power and current
consumption refer to the TB8100 Specifications Manual.
Table 4.3 Power Saving measures selected by receiver cycling time
Power
Saving
Mode
Receiver
Cycling
Reciter Power Rails
PWR_ON PWD_EX PWD_RX
Normal No cycling on on on
5ms on on cycling
10ms on on cycling
20ms on on cycling
Sleep No cycling on on on
20ms on on cycling
50ms on on cycling
100ms on on cycling
200ms cycling off cycling
Deep
Sleep
No cycling on on on
200ms cycling off cycling
500ms cycling off cycling
1s cycling off cycling
5 s cycling off cycling