53
CONTROLS
2. Stop the engine and open the selector
valve (1) on the machine body.
(The residual pressure is released from
the (b) port line.)
When equipped with accumulator (option):
Refer to page 232 “Accumulator”.
Selector valve
O: Open .......When using a hydraulic
breaker (1-way flow)
S: Closed..... When using a reversible
attachment (2-way flow)
Change the direction of the hydraulic oil flow
by opening or closing the selector valve on
the machine body.
Accessories
External Power Sockets (for EU)
IMPORTANT: Only use applicable electric
products with these sockets.
for Beacon
Use these sockets as an external power
supply. When using these sockets, be
careful not to exceed 12V/10A.
To use, raise the cap (1).
1 - way
2 - way
1
1
O
S
G4D007E
C4C0281
1
1
N0C008