EasyManua.ls Logo

Tamron MP3010M-EV - VISCA Interface Commands; VISCA Interface and Inquiry

Tamron MP3010M-EV
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tamron Co., Ltd.
53 / 79
Packet Note
Address 88 30 01 FF Always broadcasted.
Network Change X0 38 FF
X = 9 to F: camera address +8
VISCA Interface Commands
IF_Clear Command
Clears the command buffers in the camera and cancels the command currently
being executed.
Command Packet Reply Packet Note
IF_Clear 8X 01 00 01 FF X0 50 FF
IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF
X = 1 to 7: camera address (For inquiry packet)
X = 9 to F: camera address +8 (For reply packet)
VISCA Interface and Inquiry
CAM_VersionInq
Returns information of the VISCA interface.
Inquiry Inquiry Packet Reply Packet Description
CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID (0023: TAMRON)
HHHH = Model ID
(F017 : MP3010M-EV)
JJJJ = ROM revision
KK = Maximum socket #(02)
X = 1 to 7: camera address (For inquiry packet)
Y = 9 to F: camera address +8 (For reply packet)