EasyManua.ls Logo

Tamron MP3010M-EV - Error Messages; Network Change Message

Tamron MP3010M-EV
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tamron Co., Ltd.
55 / 79
Error Messages
Command Message
Comments
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a
command with illegal command parameters is accepted.
Command Buffer Full
z0 60 03 FF
Indicates that two sockets are already being used (executing
two commands) and the command could not be accepted when
received.
Command Canceled
z0 6y 04 FF(y:Socket No.)
Returned when a command which is being executed in a socket
specified by the cancel command is canceled. The completion
message for the command is not returned.
No Socket
z0 6y 05 FF(y:Socket No.)
Returned when no command is executed in a socket specified
by the cancel command, or when an invalid socket number is
specified.
Command Not Executable
z0 6y 41 FF(y:Socket No.)
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
z = 9 to F: Device address +8
Network Change Message
Command Message
Comments
Network Change
z0 38 FF
Issued when power is being routed.
z = 9 to F: Device address +8

Table of Contents