EasyManuals Logo

Taylor PH61 User Manual

Taylor PH61
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
8-2
TROUBLESHOOTING GUIDE
PH61 Peristaltic Pump
Troubleshooting Guide
8
5. The product is too thick. a. Not enough syrup - 1 fluid oz.
(30 ml) in 5 seconds.
a. Calibrate the syrups. Check that the syrup tanks
have an adequate syrup supply.
b. Insufficient mix in the freezing
cylinder.
b. Check the air/mix pump assembly.
c. Improper priming procedures. c. Drain the freezing cylinder and reprime the machine.
d. Air/mix pump incorrectly
assembled.
d. Follow assembly procedures carefully.
e. The viscosity control is set too
cold.
e. Call a Taylor service technician.
f. Freeze-up in mix inlet hole. f. Call a Taylor service technician.
6. Product is too soft. a. Too much syrup - 1 fluid oz. (30 ml)
in 5 seconds.
a. Calibrate syrups.
b. Outdrawing capacity of freezing
cylinder.
b. Continuous draw rate is approximately one 16 oz.
(473 ml) shake by volume every 15 to 20 seconds.
c. Inadequate airspace. c. Minimum of 6 in. (152 mm) airspace around all
sides.
d. Dirty condenser or air filters on
air-cooled machines.
d. Clean regularly.
e. Inadequate water supply on
water-cooled machines.
e. Check the water supply. Check the water lines for
leaks or kinks.
f. Bad scraper blades. f. Replace the scraper blades.
g. The viscosity control is set too
warm.
g. Call a Taylor service technician.
h. Air passage is blocked in the
pump.
h. Brush-clean the pump components and reassemble.
7. The mix in the hopper is
too warm.
a. Hopper cover is not in position. a. Clean the hopper cover and place in position.
b. The agitator is not installed. b. Clean the agitator and install.
c. The hopper temperature is out of
adjustment.
c. Call a Taylor service technician.
8. The mix in hopper is too
cold.
a. The hopper temperature is out of
adjustment.
a. Call a Taylor service technician.
9. Product is collecting on
top of draw valve.
a. Inadequate lubrication of spinner
shaft or seal.
a. Lubricate properly.
b. Spinner shaft seal is missing or
worn.
b. Install or replace the spinner shaft seal.
10.Product is collecting on
top of the freezer door.
a. The top O-ring on draw valve is
improperly lubricated or worn.
a. Lubricate properly or replace the O-ring.
11.Excessive mix leakage
from the bottom of door
spout.
a. Bottom O-ring on draw valve is
improperly lubricated or worn.
a. Lubricate properly or replace the O-ring.
Problem Probable Cause Corrective Action

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor PH61 and is the answer not in the manual?

Taylor PH61 Specifications

General IconGeneral
BrandTaylor
ModelPH61
CategoryFreezer
LanguageEnglish

Related product manuals