EasyManua.ls Logo

TDK-Lambda Genesys GEN8-300 - Connecting Power Supplies to Rs232 or Rs485 Bus; Single Power Supply

TDK-Lambda Genesys GEN8-300
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
7.4 CONNECTINGPOWER SUPPLIES TO RS232 OR RS485 BUS
7.4.1 Single power supply
1. Select the desired interface RS232 or RS485 using rear panel setup switch SW1-6 (section 4-4).
- RS232: Down position
- RS485: Up position
2. Connect rear panel IN connector to the controller RS232 or RS485 port using a suitable shielded
cable. Refer to Figures 7-2, 7-3 and 7-4 for available RS232 and RS485 cables.
2
3
7
1
8
7
1
HOUSING
PIN NO.
PIN NO.NAME
NAME
SHIELD
TX
RX
SG
SHIELD
RX
TX
SG
DB-25 CONNECTOR
8 PIN CONNECTOR
REMARKS
TWISTED
PAIR
8
1
13
1
2
3
5
7
8
1
PIN NO.
HOUSING
HOUSING
PIN NO.NAME
NAME
SHIELD
RX
TX
SG
SHIELD
TX
RX
SG
DB-9 CONNECTOR
8PIN CONNECTOR
REMARKS
TWISTED
PAIR
8
1
5
1
9
8
1
5
4
6
3
1
5
4
PIN NO.
HOUSING
HOUSING
PIN NO.NAME
NAME
TWISTED
PAIR
TWISTED
PAIR
SHIELD
TXD
TXD
SG
RXD
RXD
SHIELD
RXD
RXD
SG
TXD
TXD
DB-9 CONNECTOR
8 PIN CONNECTOR
REMARKS
-
+
+
+
+
-
-
-
8
1
5
1
Fig.7-2: RS232 cable with DB25 connector (P/N: GEN/232-25)
Fig.7-3: RS232 cable with DB9 connector (P/N: GEN/232-9)
Fig.7-4: RS485 cable with DB9 connector (P/N: GEN/485-9)
L=2m typ.
L=2m typ.
L=2m typ.
Socket
Socket
Socket