30
*OPC
To activate, write 0x0001 as parameter.
*OPT?
Returns 2 for MODBUS TCP interface.
*RST
To activate, write 0x0001 as parameter.
*TRG
To activate, write 0x0001 as parameter.
*WAI
To activate, write 0x0001 as parameter.
ABORt
To activate, write 0x0001 as parameter.
INITiate[:IMMediate]
To activate, write 0x0001 as parameter.
INSTrument:COUPle
NONE – write 0x0000; ALL - write 0x0001 as parameter.
GLOBAL:*RST
To activate, write 0x0001 as parameter.
OUTPut:ENA:POLarity
REV - 0x0000; NORM – 0x0001 as return value.
OUTPut:MODE?
OFF - 0x0001; CV – 0x0002; CC - 0x0003; CP – 0x0004 as return value.
OUTPut:PROTection:CLEar
To activate, write 0x0001 as parameter.
OUTPut:PROTection:FOLDback[:MODE]
OFF - 0x0000; CC – 0x0001; CV - 0x0002 as return value.
OUTPut:PROTection:FOLDback:DELay
Unit 100mSec. Multiply register value by 100mSec. For example: 1 equals 100mec;