16. ERROR MESSAGE TABLE
16. ERROR MESSAGE TABLE
16- 2
Label lssue Mode
Report and Reset Mode
Message Cause Solution
DATA ENTRY ERROR Error in key input. Press the key, and re-input the right
data.
PLU NOT FOUND The PLU # being called out is
not registered.
Press the key, and check the PLU #.
TOTALS OVERFLOW GRAND TOTAL or PLU TOTAL
memory has been exceeded at
the time of issuing a label.
Press the key, then the key and
select RESET. Then sum up the
exceeded memory.
MEMORY WILL BE
FULLED
The machine judges the
memory is full before
designated number of media
are printed in Batch mode.
Press the key, then the key and
select RESET. Then sum up the
exceeded memory.
PLU DATA ERROR Error in the PLU data. Press the key, and reprogram PLU
data.
PRT FAILURE DETECTED Printer trouble.
Media end.
1. Check that the label and print head are
set correctly.
2. If the label home position is misaligned,
press the key.
LABEL OVER RUN Label overruns. Press the key.
Message Cause Solution
PLU NOT FOUND Corresponding PLU # is not
registered.
Press the key, and enter the correct
PLU #.
PRT FAILURE DETECTED Printer trouble. Same as in the label issue mode.
LABEL OVER RUN Label overruns. Press the key.
C
C
C
ESC.
C
FEED
FEED
C
ESC.
C
FEED

Table of Contents