Set the chassis ID by changing the dipswitch settings as shown below in Figure 12.
The default IP address of each COM46 card in a system is determined by the chassis ID and slot
number the card is installed in.
The formula for determining this address is 192.168.3.[1 + (chassis ID X 16) + slot number].
Example for chassis one:
1 + (16*1) + 1 = 18 IP address of chassis one slot one is 192.168.3.18
Chassis ID
Switch 1
Switch 2
Switch 3
Switch 4
Default IP Slot 1
1
UP
DOWN
DOWN
DOWN
192.168.3.18
2
DOWN
UP
DOWN
DOWN
192.168.3.34
3
UP
UP
DOWN
DOWN
192.168.3.50
4
DOWN
DOWN
UP
DOWN
192.168.3.66
5
UP
DOWN
UP
DOWN
192.168.3.82
6
DOWN
UP
UP
DOWN
192.168.3.98
7
UP
UP
UP
DOWN
192.168.3.114
8
DOWN
DOWN
DOWN
UP
192.168.3.130
9
UP
DOWN
DOWN
UP
192.168.3.146
10
DOWN
UP
DOWN
UP
192.168.3.162
11
UP
UP
DOWN
UP
192.168.3.178
12
DOWN
DOWN
UP
UP
192.168.3.194
13
UP
DOWN
UP
UP
192.168.3.210
14
DOWN
UP
UP
UP
192.168.33.36
Figure 12 - Dipswitch Settings for Multiple Chassis