RS・『R575
■MEASUREMENTS AND ADJUSTMENTS
Measu『ement Condition
●Recording・level controll Maximum
●Recording・balance controll Center
●Reverse・mode selector switch;ロ
●Tape−to−tape recording−speed switch;Off
●Dolby NR switch;Off
●ATC switchl Off
●Makesure headsareclean
●Make sure capstan and pressure roIIer are clean
●Judgeable room temperature20±5。C(68±9。F)
Measu『ing inst『umen量
●EVM(Electronic Voltmeter) ●ATT(Attenuator)
●Oscilloscope ●DC voltmeter
●Digital frequency counter ●Resistor(600Ω)
●AF osclllator
NOTE=Before adjustment,be sure to set the AF oscillator output Ievel to OdB(1kHz》:1V
Tes電tape
:灘撚黙)1・一
・Tape speed adjustment(3kHz,一10dB》;Q互CWAT
●OveraII gain adjustment and Overafrequency response
Normal reference blank tape;QZZCRA
CrO2reference blank tapel QZZCRX
Metal reference blank tapel QZZCRZ
●Adjustment Points
Tope speed
DECK
Tope speed
lDECK2:Highl
Tope speed
⊂DECK21
VR801
MOTOR RC.B.⊂DECKけ
VR802
VR803
MOTOR RC.B,⊂DECK2》
OPERATION RC.B。
◇
Shor†qip
亘)
Notes=
●The test mode terminals on mechanism control P.C.B.
should be shorted wlth a short clip as shown above
figure.
●After the adjustment items dlsconnect the short clip.
一31一