D
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C
24/31
DPreventive maintenance
The maintenance operations listed here are intended as a guideline, and should be implemented upon reception
of the material. In a highly polluted environment, these operations may need to be performed more frequently.
1. Every week
• Empty the air filter in order to eliminate dust or liquid which
may be present in the system. Clean, dry, non-lubricated
air will reduce the build-up of grease in the solenoid valves.
This will ensure optimal functioning and reliability of the
stylus.
1 : Guide rails
2. Every month
• Dismantle the stylus.
• Check the condition of the stylus, then clean it
thoroughly.
• Clean the point with a dry cloth.
• If the point’s radius is too deformed (wider marking,
more burrs on the part marked), replace the point with
a new one.
1 : Body
2 : Spring
3 : Point
4 : Piston seal
5 : O-ring
Unplug the power supply plug before beginning any cleaning or maintenance operation.
Do not apply oil or grease to any element of the stylus or marking head.
Never use pliers to tighten the stylus.
Operating pressure: 1 Bar (14.504 PSI) to 8 Bar (116.03 PSI)
The air must be clean and dry.
Check the compressed air system regularly. Based on the level of contamination, establish a schedule
for cleaning or replacement.
XF510Cr/Sr/Dr - Top view
1
15432