AIntroduction
A
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C
5/31
5. Work station safety
To ensure security and productivity, read this manual before starting-up the equipment.
This marking equipment is designed to function at a room temperature between 5
0
C (41
0
F) to 45
0
C (113
0
F).
Do not use this marking equipment in an explosive environment.
This marking equipment is not designed to operate in damp premises.
Grounding must be done according to the regulations in effect to ensure the safety of the personnel. The
connection to the single phase power supply is made with a standard, 3 pin plug with grounding. It must be
equipped with an adequately calibrated 30 mA differential cut-off and protection device.
Never hold with your hands the part to mark: clamp the part mechanically. Locking during marking must be
strong and stable considering the vibrations and force during marking. If the part moves, the point may be
damaged, thus making it unusable.
Never unplug a cable while the Control Unit is turned on.
Never lubricate the X-Y carriage guiding rails. They must remain clean.
Do not remove the machine’s casing: risk of electric shock.
The compressed air system must meet all standards.
Use only clean, dry, non-lubricated air.
Never connect the machine to a pneumatic circuit containing air pressure higher than 8 Bar (116.03 PSI).
The air exhaust from the stylus can project metal dust or chips, if necessary wear safety glasses.
When the machine is used on a column without an exterior protection system, mount mobile shutters or
protective boot.
Instructions for use and warranty limitations
This equipment is designed to mark material using Technifor scribing styli only. Any other use, or the
use of styli other than those provided by Technifor is not recommended. Technifor will not be held
responsible for the results.
At the time of disposal, wearing personal protective equipment (PPE) is
recommended to dismantle the mechanical elements of the machine. Some guiding
elements are to be dismantled when hot and may release toxic fumes.