6.7.3.1.2 VALUE ≤ ±10% OF THE STANDARD VALUE
Ifacalibrationerrorappearsandthevalueshownonthedisplayis≤±10%ofthestandardvalue
and therefore:
CALIBRATION RESULTS VALUE RANGE
DIFFERENCE BETWEEN TWO
ADJACENT LEVELS
90≤x≤242
DIFFERENCE BETWEEN EFFORT
LEVEL10ANDEFFORTLEVEL0
1350≤x≤2310
Table 62
- Repeat the calibration twice more.
- If the calibration error persists but the value shown on the display is within the range shown
in “Table 62”, carry out the following test (without repeating the calibration): move the lever and
make sure the levels are activated in the right order, that they change on the basis of the lever
movement, and that the values on the display are stable.
- If the outcome of the test is positive ("OK"), no further action is required and the machine
will store the last calibration in its memory. The calibration is acceptable when the delta between
twoadjacentlevelsis≤±10%oftherangeofacceptablevalues.Iftheoutcomeisnegative("not
OK"), repeat the calibration procedure.
6.8 PROCEDURE FOR SETTING THE DATE AND TIME
1. Launch the following commands from the terminal without disconnecting the USB - MINI
USB cable:
2. Initialise the RTC (Real Time Clock) using the command @RTCINIT#
3. CongurethedateandtimeintheRTCusingthecommand
@SETDATEddmmyyyyhhmnss#
Enter the following information:
▪ dd: day of the month
▪ mm: month
▪ yyyy: year
▪ hh: hours
▪ mn: minutes
▪ ss: seconds
▪ :timezone;theminutesofdeviationfromUTCmustbeentered.Ifyouarelocatedeastof
Greenwich, the value will be positive, otherwise it will be negative. As a reference for Italy, when
StandardTimeisbeingused,thedeviationis+60minutes,whereasitis+120minutesduring
Daylight Saving Time. If you enter the time, set UTC to 0.