Page 5 - 11
Section 5 - Performances
TAKE-OFF RATE OF CLIMB
2
nd
Edition, Rev. 0
8. TAKE-OFF RATE OF CLIMB
To account for likely in service performance variations apply a
factored to rate of climb of 0.90
Throttle Lever: Full Forward
Flaps: Take-Off
Weight
Pressure
Altitude
Climb
Speed
V
y
Rate of Climb [ft/min]
Temperature [°C]
ISA
[kg]
([lb])
[ft]
[KIAS]
-25
0
25
50
1160
(2557)
S.L.
72
1008
816
644
490
711
2000
72
862
673
504
352
596
4000
72
716
531
365
216
482
6000
72
571
389
226
79
368
8000
72
427
247
87
-57
253
10000
72
283
107
-51
-192
139
12000
72
139
-34
-188
-327
25
14000
72
-4
-174
-325
-462
-90
1060
(2337)
S.L.
72
1162
956
772
606
843
2000
72
1005
803
622
459
721
4000
72
849
650
472
312
598
6000
72
694
498
323
166
476
8000
72
539
346
175
20
353
10000
72
384
195
27
-125
230
12000
72
230
45
-121
-270
108
14000
72
77
-105
-268
-414
-15
960
(2116)
S.L.
71
1343
1120
920
741
997
2000
71
1173
954
758
581
865
4000
71
1004
788
596
422
732
6000
71
835
623
434
263
599
8000
71
667
459
273
105
466
10000
71
500
295
113
-52
333
12000
72
333
132
-47
-209
200
14000
72
166
-31
-207
-365
67