Page 3 - 5
Section 3 Emergency procedures
ALTERNATOR FAILURE
2
nd
Edition, Rev.0
2. FAILURES INDICATED ON THE ANNUNCIATION WINDOW
The annunciator window is integrated in the GARMIN G1000. The colours are
as follows:
GREEN: to indicate that pertinent device is turned ON
AMBER: to indicate no-hazard situations which have to be considered and
which require a proper crew action
RED: to indicate emergency conditions
2.1. ALTERNATOR FAILURE
Annunciation window
Alert window
ALT FAIL
Alternator failure
If ALT FAIL caution is ON:
1. Circuit breaker(s)……………………...
Check
2. Generator SWITCH………………...…
OFF
3. Generator SWITCH…………………...
ON
If ALT FAIL CAUTION REMAINS on:
4. Generator SWITCH………………...…
OFF
A fully charged battery shall supply electrical power for at least 30
minutes.
NOTE